Axis Info Attributes

These are the attributes that provide information about the associated hardware capabilities of the Motion Control Axis.
Inverter Rated Output Voltage
Usage
Access
T
Data Type
Default
Min
Max
Semantics of Values
Required - D Optional - X
!LTM
Get
REAL
-
-
-
Volts (RMS)
The Inverter Rated Output Voltage attribute is the drive inverter output voltage rating. This value is hard coded in the device.
Inverter Rated Output Current
Usage
Access
T
Data Type
Default
Min
Max
Semantics of Values
Required - D
Optional - X
!LTM
Get
REAL
-
-
-
Amps (RMS)
The Inverter Rated Output Current attribute is the drive inverter output current rating. This value is hard coded in the device.
Inverter Rated Output Power
Usage
Access
T
Data Type
Default
Min
Max
Semantics of Values
Required - D
Optional - X
!LTM
Get
REAL
-
-
-
Kilowatts
The Inverter Rated Output Power attribute is the drive inverter output power rating. This value is hard coded in the device.
Converter Rated Output Current
Usage
Access
T
Data Type
Default
Min
Max
Semantics of Values
Optional - BD
Get
REAL
-
-
-
Amps
The Converter Rated Output Current attribute is the converter output current rating.
Converter Rated Output Power
Usage
Access
T
Data Type
Default
Min
Max
Semantics of Values
Optional - BD
Get
REAL
-
-
-
Kilowatts
The Converter Rated Output Power attribute is the converter output power rating.
Converter Rated Output Voltage
Usage
Access
T
Data Type
Default
Min
Max
Semantics of Values
Optional - BD
Get
REAL
-
-
-
Volts
The Converter Rated Output Voltage attribute is the converter output voltage rating.
Converter Rated Input Current
Usage
Access
T
Data Type
Default
Min
Max
Semantics of Values
Optional - BD
Get
REAL
-
-
-
Amps (RMS)
The Converter Rated Input Current attribute is the converter input current rating.
Converter Rated Input Power
Usage
Access
T
Data Type
Default
Min
Max
Semantics of Values
Optional - BD
Get
REAL
-
-
-
Kilowatts
The Converter Rated Input Power attribute is the converter input power rating.
Converter Rated Input Voltage
Usage
Access
T
Data Type
Default
Min
Max
Semantics of Values
Optional - BD
Get
REAL
-
-
-
Volts (RMS)
The Converter Rated Input Voltage attribute is the converter input voltage rating.
Drive Power Structure Axis ID
Usage
Access
T
Data Type
Default
Min
Max
Semantics of Values
Optional - D
Get
UDINT
-
-
-
ID#
The Drive Power Structure Axis ID attribute identifies the power structure with the axis instance.
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.