Communication Protocol | DeviceNet |
---|---|
Power Supply | 24V DC |
Temperature Rating | -20…65 °C (-4…149 °F) |
Suitable for safety functions | False |
---|---|
With optical interface | False |
Supporting protocol for TCP/IP | False |
Supporting protocol for DeviceNet | True |
Supporting protocol for other bus systems | False |
Redundancy | False |
IO link master | False |
Supporting protocol for DeviceNet Safety | False |
Supporting protocol for EtherNet/IP | False |
Power dissipation, max | 1.44 W |
Data transmission type | DeviceNet |
Enclosure type rating | Meets IP20 |
Number of nodes, max | 20 nodes for I/O ops |
Wire category | 1 - on power ports |
Wire size | 0.25...2.5 mm2 (24...14 AWG) solid copper wire, 0.25...2.5 mm2 (24...14 AWG) stranded copper wire, Rated @ 75 °C (167 °F ), or greater, 1.2 mm (3/64 in.) insulation maximum |
Isolation voltage | 50V (continuous), Type tested for 60 s @ 500V AC |
Supporting protocol for LON | False |
Supporting protocol for ASI | False |
Supporting protocol for PROFIBUS | False |
Supporting protocol for CAN | False |
Supporting protocol for INTERBUS | False |
Supporting protocol for KNX | False |
Supporting protocol for Modbus | False |
Supporting protocol for Data-Highway | False |
Supporting protocol for SUCONET | False |
With potential separation | False |
Supporting protocol for SERCOS | False |
Supporting protocol for INTERBUS-Safety | False |
Supporting protocol for AS-Interface Safety at Work | False |
Supporting protocol for Foundation Fieldbus | False |
Supporting protocol for PROFINET CBA | False |
Supporting protocol for PROFINET IO | False |
Supporting protocol for PROFIsafe | False |
Supporting protocol for SafetyBUS p | False |
SIL according to IEC 61508 | None |
Preferred power supply | 1606-XLSDNET4 |
Backplane power consumption | 50mA @ 24V DC |
DeviceNet current | 24V DC @ 300mA Class 2 |
Network protocol | I/O Slave messaging: poll command |
DeviceNet status indicators | Module status - red/green Network status - red/green |
DeviceNet communication rate, max | 125 Kbps - 420 m (1378 ft.), 250 Kbps - 200 m (656 ft.), 500 Kbps - 75 m (246 ft.) |
Width | 31.5 mm |
---|---|
Height | 62 mm |
Depth | 20 mm |
Weight | 35 g |
Surrounding air temperature, max | 65 °C |
---|---|
Emissions | CISPR 11 (IEC 61000-6-4): Class A |
Vibration | IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz |
ESD immunity | IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges |
EFT/B immunity | IEC 61000-4-4: ± 2kV @ 5kHz on communication ports |
Relative humidity | IEC 60068-2-30 (Test Db, unpackaged dA heat), 5...95% noncondensing |
Shock | Operating: 25 G, IEC 60068-2-27 (Test Ea, unpackaged shock) |
Conducted RF immunity | IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
Surge transient immunity | IEC 61000-4-5: ± 2 kV line-earth(CM) on communication ports |
Nonoperating temperature | -40...85 °C (-40...185 °F), IEC60068-2-1 (Test Ad, operating cold), IEC60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock) |
Operating temperature | -20...65 °C (-4...149 °F), IEC 60068-2-1 (Test Ad, operating cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock) |
Radiated RF immunity | IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz, |
North American temperature code | T4 |
---|---|
Explosion safety category for gas | None |
Explosion safety category for dust | None |
Sales Info
Repairable | NOT_REPAIRABLE |
Preferred Availability | false |
Quick Turnaround | false |
Dimension Height | 2.0 |
Lead Time | 5 |
Dimension Width | 3.15 |
Dimension Length | 6.2 |
Stock Status | STOCKED |
Weight | 63.503 |
Weight Unit | G |
Dimension Unit | CM |
Drawings | |
---|---|
3D STP (STEP) Model | Download (ZIP) |
Product Drawing | Drawing (DXF) |
Drawings |
---|
3D STP (STEP) Model Download (ZIP) |
Product Drawing Drawing (DXF) |
Type | Resource | Publication |
---|---|---|
General | Installation Guide | -- |
General | Product Cutsheet | -- |
User Manual | 2080-um004_-en-e | 2080-UM004 |
User Manual | Micro800 Plug-in Modules User Manual | 2080-UM002 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center
Search the Literature Library
- Korean Register of Shippin
This product was certified with the above certifications as of 2024-11-21. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Sign in to your Rockwell Automation account to view Knowledgebase Articles.
Sign In
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
Communication Protocol | DeviceNet |
---|---|
Power Supply | 24V DC |
Temperature Rating | -20…65 °C (-4…149 °F) |
Suitable for safety functions | False |
---|---|
With optical interface | False |
Supporting protocol for TCP/IP | False |
Supporting protocol for DeviceNet | True |
Supporting protocol for other bus systems | False |
Redundancy | False |
IO link master | False |
Supporting protocol for DeviceNet Safety | False |
Supporting protocol for EtherNet/IP | False |
Power dissipation, max | 1.44 W |
Data transmission type | DeviceNet |
Enclosure type rating | Meets IP20 |
Number of nodes, max | 20 nodes for I/O ops |
Wire category | 1 - on power ports |
Wire size | 0.25...2.5 mm2 (24...14 AWG) solid copper wire, 0.25...2.5 mm2 (24...14 AWG) stranded copper wire, Rated @ 75 °C (167 °F ), or greater, 1.2 mm (3/64 in.) insulation maximum |
Isolation voltage | 50V (continuous), Type tested for 60 s @ 500V AC |
Supporting protocol for LON | False |
Supporting protocol for ASI | False |
Supporting protocol for PROFIBUS | False |
Supporting protocol for CAN | False |
Supporting protocol for INTERBUS | False |
Supporting protocol for KNX | False |
Supporting protocol for Modbus | False |
Supporting protocol for Data-Highway | False |
Supporting protocol for SUCONET | False |
With potential separation | False |
Supporting protocol for SERCOS | False |
Supporting protocol for INTERBUS-Safety | False |
Supporting protocol for AS-Interface Safety at Work | False |
Supporting protocol for Foundation Fieldbus | False |
Supporting protocol for PROFINET CBA | False |
Supporting protocol for PROFINET IO | False |
Supporting protocol for PROFIsafe | False |
Supporting protocol for SafetyBUS p | False |
SIL according to IEC 61508 | None |
Preferred power supply | 1606-XLSDNET4 |
Backplane power consumption | 50mA @ 24V DC |
DeviceNet current | 24V DC @ 300mA Class 2 |
Network protocol | I/O Slave messaging: poll command |
DeviceNet status indicators | Module status - red/green Network status - red/green |
DeviceNet communication rate, max | 125 Kbps - 420 m (1378 ft.), 250 Kbps - 200 m (656 ft.), 500 Kbps - 75 m (246 ft.) |
Width | 31.5 mm |
---|---|
Height | 62 mm |
Depth | 20 mm |
Weight | 35 g |
Surrounding air temperature, max | 65 °C |
---|---|
Emissions | CISPR 11 (IEC 61000-6-4): Class A |
Vibration | IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz |
ESD immunity | IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges |
EFT/B immunity | IEC 61000-4-4: ± 2kV @ 5kHz on communication ports |
Relative humidity | IEC 60068-2-30 (Test Db, unpackaged dA heat), 5...95% noncondensing |
Shock | Operating: 25 G, IEC 60068-2-27 (Test Ea, unpackaged shock) |
Conducted RF immunity | IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
Surge transient immunity | IEC 61000-4-5: ± 2 kV line-earth(CM) on communication ports |
Nonoperating temperature | -40...85 °C (-40...185 °F), IEC60068-2-1 (Test Ad, operating cold), IEC60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock) |
Operating temperature | -20...65 °C (-4...149 °F), IEC 60068-2-1 (Test Ad, operating cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock) |
Radiated RF immunity | IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz, |
North American temperature code | T4 |
---|---|
Explosion safety category for gas | None |
Explosion safety category for dust | None |
Sales Info
Repairable | NOT_REPAIRABLE |
Preferred Availability | false |
Quick Turnaround | false |
Dimension Height | 2.0 |
Lead Time | 5 |
Dimension Width | 3.15 |
Dimension Length | 6.2 |
Stock Status | STOCKED |
Weight | 63.503 |
Weight Unit | G |
Dimension Unit | CM |
Drawings
Drawings | |
---|---|
3D STP (STEP) Model | Download (ZIP) |
Product Drawing | Drawing (DXF) |
Drawings |
---|
3D STP (STEP) Model Download (ZIP) |
Product Drawing Drawing (DXF) |
Documents
Installation Guide
General
-- |
Product Cutsheet
General
-- |
2080-um004_-en-e
User Manual
2080-UM004 |
Micro800 Plug-in Modules User Manual
User Manual
2080-UM002 |
Type | Resource | Publication |
---|---|---|
General | Installation Guide | -- |
General | Product Cutsheet | -- |
User Manual | 2080-um004_-en-e | 2080-UM004 |
User Manual | Micro800 Plug-in Modules User Manual | 2080-UM002 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center
Search the Literature Library
Certifications
- Korean Register of Shippin
This product was certified with the above certifications as of 2024-11-21. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Technotes
Sign in to your Rockwell Automation account to view Knowledgebase Articles.
Sign In
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Find a sales and technology partner
Copyright ©2024 Rockwell Automation, Inc.