Executive Summary
Rockwell Automation received a report from the researcher William Knowles at Applied Risk regarding a vulnerability in RSLinx® Classic software, which if successfully exploited, could allow an authenticated attacker to gain elevated or SYSTEM level privileges.
Customers using affected versions of this software are encouraged to evaluate the mitigations provided below and apply the appropriate mitigations to their deployed products. Additional details relating to the discovered vulnerability, including affected products and recommended countermeasures, are provided herein.
Affected Products
RSLinx versions 4.11.00 and earlier.
Vulnerability Details
CVE-2020-10642: Privilege Escalation via Weak Registry Key Permissions
An authenticated, local attacker could modify the registry key, which could lead to the execution of malicious code when RSLinx Classic was opened. The code would run under the same system privileges as RSLinx and therefore, could be used for privilege escalation.
CVSS v3.0 Base Score: 8.8/HIGH
CVSS v3.0 Vector String: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Risk Mitigation & User Action
Customers using the affected versions of RSLinx Classic are encouraged to update to an available software version that addresses the associated risk. Customers who are unable to update are directed towards the risk mitigation strategies provided below and are encouraged, when possible, to combine these with the general security guidelines to employ multiple strategies simultaneously.
Product Family | Suggested Actions |
RSLinx Classic | Apply Patch 1091155 (Download). The patch can be applied to v3.60 to v4.11, but customers are encouraged to apply the most recent version of RSLinx Classic. |
General Security Guidelines
- Run all software as User, not as an Administrator, to minimize the impact of malicious code on the infected system.
- Use of Microsoft® AppLocker or other similar whitelisting application can help mitigate risk. Information on using AppLocker with Rockwell Automation products is available at Knowledgebase Article ID 546989.
- Ensure that the least-privilege user principle is followed and user/service account access to shared resources (such as a database) is only granted with a minimum amount of rights as needed.
- Use trusted software, software patches, antivirus/antimalware programs and interact only with trusted web sites and attachments.
For further information on the Vulnerability Handling Process for Rockwell Automation, please refer to our Product Security Incident Response FAQ document.
See our Industrial Network Architectures Page for comprehensive information about implementing validated architectures designed to complement security solutions.
Refer to the Network Services Overview Page for information on network and security services for Rockwell Automation to enable assessment, design, implementation and management of validated, secure network architectures.
We also recommend that concerned customers continue to monitor this advisory by subscribing to updates on the Security Advisory Index for Rockwell Automation, at: 54102 - Industrial Security Advisory Index.
Rockwell Automation remains committed to making security enhancements to our systems in the future. For more information and for assistance with assessing the state of security of your existing control system, including improving your system-level security when using Rockwell Automation and other vendor controls products, you can visit the Rockwell Automation Security Solutions website.
Requests for additional information can be sent to the RASecure Inbox (rasecure@ra.rockwell.com).
Please direct all media inquiries to Kolve Byrd (KAByrd@ra.rockwell.com).
ADDITIONAL LINKS