Device-defined data types (Stratix 5200 10 Port Managed Switch, Input Data Type)
The tables below list and describe device-defined data types for the Stratix 5200 10 Port Managed Switch, Input Data Type. These tables include information for input (as indicated by an I) and output (as indicated by an O).
Member Name | Type | Default Display Style | Valid Values |
---|---|---|---|
DINT Fault (Radix = Binary); DINT LinkStatus (Radix = Binary) (Hidden = True); | DINT | Binary | |
AnyPortConnected | BOOL | Decimal | LinkStatus:0 |
PortGi1_1Connected | BOOL | Decimal | LinkStatus:1 |
PortGi1_2Connected | BOOL | Decimal | LinkStatus:2 |
PortFa1_3Connected | BOOL | Decimal | LinkStatus:3 |
PortFa1_4Connected | BOOL | Decimal | LinkStatus:4 |
PortFa1_5Connected | BOOL | Decimal | LinkStatus:5 |
PortFa1_6Connected | BOOL | Decimal | LinkStatus:6 |
PortFa1_7Connected | BOOL | Decimal | LinkStatus:7 |
PortFa1_8Connected | BOOL | Decimal | LinkStatus:8 |
PortFa1_9Connected | BOOL | Decimal | LinkStatus:9 |
PortFa1_10Connected | BOOL | Decimal | LinkStatus:10 |
Pad1 (Hidden = True) | DINT | Decimal | |
DINT UnauthorizedDevice (Radix = Binary) (Hidden = True); | |||
AnyPortUnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:0 |
PortGi1_1UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:1 |
PortGi1_2UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:2 |
PortFa1_3UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:3 |
PortFa1_4UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:4 |
PortFa1_5UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:5 |
PortFa1_6UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:6 |
PortFa1_7UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:7 |
PortFa1_8UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:8 |
PortFa1_9UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:9 |
PortFa1_10UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:10 |
Pad2 (Hidden = True) | DINT | Decimal | |
DINT ThresholdExceeded (Radix = Binary) (Hidden = True); | |||
AnyPortThreshold | BOOL | Decimal | ThresholdExceeded:0 |
PortGi1_1Threshold | BOOL | Decimal | ThresholdExceeded:1 |
PortGi1_2Threshold | BOOL | Decimal | ThresholdExceeded:2 |
PortFa1_3Threshold | BOOL | Decimal | ThresholdExceeded:3 |
PortFa1_4Threshold | BOOL | Decimal | ThresholdExceeded:4 |
PortFa1_5Threshold | BOOL | Decimal | ThresholdExceeded:5 |
PortFa1_6Threshold | BOOL | Decimal | ThresholdExceeded:6 |
PortFa1_7Threshold | BOOL | Decimal | ThresholdExceeded:7 |
PortFa1_8Threshold | BOOL | Decimal | ThresholdExceeded:8 |
PortFa1_9Threshold | BOOL | Decimal | ThresholdExceeded:9 |
PortFa1_10Threshold | BOOL | Decimal | ThresholdExceeded:10 |
Pad3 (Hidden = True) | DINT | Decimal | |
SINT AllPortsUtilization; SINT PortGi1_1Utilization; SINT PortGi1_2Utilization; SINT PortFa1_3Utilization; SINT PortFa1_4Utilization; SINT PortFa1_5Utilization; SINT PortFa1_6Utilization; SINT PortFa1_7Utilization; SINT PortFa1_8Utilization; SINT PortFa1_9Utilization; SINT PortFa1_10Utilization; SINT PortFa1_11Utilization(Hidden=True); SINT PortFa1_12Utilization(Hidden=True); SINT PortFa1_13Utilization(Hidden=True); SINT PortFa1_14Utilization(Hidden=True); SINT PortFa1_15Utilization(Hidden=True); SINT PortFa1_16Utilization(Hidden=True); SINT PortFa1_17Utilization(Hidden=True); SINT PortFa1_18Utilization(Hidden=True); SINT PortFa1_19Utilization(Hidden=True); SINT PortFa1_20Utilization(Hidden=True); SINT PortFa1_21Utilization(Hidden=True); SINT PortFa1_22Utilization(Hidden=True); SINT PortFa1_23Utilization(Hidden=True); SINT PortFa1_24Utilization(Hidden=True); SINT PortFa1_25Utilization(Hidden=True); SINT PortFa1_26Utilization(Hidden=True); SINT Pad4 (Hidden=True); SINT Pad5 (Hidden=True); SINT Pad6 (Hidden=True); SINT Pad7 (Hidden=True); SINT Pad8 (Hidden=True); SINT Pad9 (Hidden=True); SINT Pad10 (Hidden=True); SINT Pad11 (Hidden=True); SINT Pad12 (Hidden=True); SINT Pad13 (Hidden=True); SINT Pad14 (Hidden=True); SINT Pad15 (Hidden=True); SINT Pad16 (Hidden=True); SINT Pad17 (Hidden=True); SINT Pad18 (Hidden=True); SINT Pad19 (Hidden=True); SINT Pad20 (Hidden=True); SINT Pad21 (Hidden=True); SINT Pad22 (Hidden=True); SINT Pad23 (Hidden=True); SINT Pad24 (Hidden=True); SINT Pad25 (Hidden=True); SINT Pad26 (Hidden=True); SINT Pad27(Hidden=True); SINT Pad28(Hidden=True); SINT Pad29 (Hidden=True); SINT Pad30(Hidden=True); SINT Pad31 (Hidden=True); SINT Pad32 (Hidden=True); SINT Pad33(Hidden=True); SINT Pad34 (Hidden=True); SINT Pad35(Hidden=True); SINT Pad36(Hidden=True); SINT Pad37 (Hidden=True); SINT Pad38 (Hidden=True); SINT Pad39(Hidden=True); SINT Pad40(Hidden=True); DINT AlarmRelay(Radix = Binary) (Hidden = True); Bit MajorAlarmRelay AlarmRelay: 0; DINT MulticastGroupsActive (Radix = Binary); END_DATATYPE |
Member Name | Type | Default Display Style | Valid Values |
---|---|---|---|
DINT Fault (Radix = Binary); DINT LinkStatus (Radix = Binary) (Hidden = True); | DINT | Binary | |
AnyPortConnected | BOOL | Decimal | LinkStatus:0 |
PortGi1_1Connected | BOOL | Decimal | LinkStatus:1 |
PortGi1_2Connected | BOOL | Decimal | LinkStatus:2 |
PortGi1_3Connected | BOOL | Decimal | LinkStatus:3 |
PortGi1_4Connected | BOOL | Decimal | LinkStatus:4 |
PortGi1_5Connected | BOOL | Decimal | LinkStatus:5 |
PortGi1_6Connected | BOOL | Decimal | LinkStatus:6 |
PortGi1_7Connected | BOOL | Decimal | LinkStatus:7 |
PortGi1_8Connected | BOOL | Decimal | LinkStatus:8 |
PortGi1_9Connected | BOOL | Decimal | LinkStatus:9 |
PortGi1_10Connected | BOOL | Decimal | LinkStatus:10 |
Pad1 (Hidden = True) | DINT | Decimal | |
DINT UnauthorizedDevice (Radix = Binary) (Hidden = True); | |||
AnyPortUnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:0 |
PortGi1_1UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:1 |
PortGi1_2UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:2 |
PortGi1_3UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:3 |
PortGi1_4UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:4 |
PortGi1_5UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:5 |
PortGi1_6UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:6 |
PortGi1_7UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:7 |
PortGi1_8UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:8 |
PortGi1_9UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:9 |
PortGi1_10UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:10 |
Pad2 (Hidden = True) | DINT | Decimal | |
DINT ThresholdExceeded (Radix = Binary) (Hidden = True); | |||
AnyPortThreshold | BOOL | Decimal | ThresholdExceeded:0 |
PortGi1_1Threshold | BOOL | Decimal | ThresholdExceeded:1 |
PortGi1_2Threshold | BOOL | Decimal | ThresholdExceeded:2 |
PortGi1_3Threshold | BOOL | Decimal | ThresholdExceeded:3 |
PortGi1_4Threshold | BOOL | Decimal | ThresholdExceeded:4 |
PortGi1_5Threshold | BOOL | Decimal | ThresholdExceeded:5 |
PortGi1_6Threshold | BOOL | Decimal | ThresholdExceeded:6 |
PortGi1_7Threshold | BOOL | Decimal | ThresholdExceeded:7 |
PortGi1_8Threshold | BOOL | Decimal | ThresholdExceeded:8 |
PortGi1_9Threshold | BOOL | Decimal | ThresholdExceeded:9 |
PortGi1_10Threshold | BOOL | Decimal | ThresholdExceeded:10 |
Pad3 (Hidden = True) | DINT | Decimal | |
SINT AllPortsUtilization; SINT PortGi1_1Utilization; SINT PortGi1_2Utilization; SINT PortGi1_3Utilization; SINT PortGi1_4Utilization; SINT PortGi1_5Utilization; SINT PortGi1_6Utilization; SINT PortGi1_7Utilization; SINT PortGi1_8Utilization; SINT PortGi1_9Utilization; SINT PortGi1_10Utilization; SINT PortGi1_11Utilization(Hidden=True); SINT PortGi1_12Utilization(Hidden=True); SINT PortGi1_13Utilization(Hidden=True); SINT PortGi1_14Utilization(Hidden=True); SINT PortGi1_15Utilization(Hidden=True); SINT PortGi1_16Utilization(Hidden=True); SINT PortGi1_17Utilization(Hidden=True); SINT PortGi1_18Utilization(Hidden=True); SINT PortGi1_19Utilization(Hidden=True); SINT PortGi1_20Utilization(Hidden=True); SINT PortGi1_21Utilization(Hidden=True); SINT PortGi1_22Utilization(Hidden=True); SINT PortGi1_23Utilization(Hidden=True); SINT PortGi1_24Utilization(Hidden=True); SINT PortGi1_25Utilization(Hidden=True); SINT PortGi1_26Utilization(Hidden=True); SINT Pad4 (Hidden=True); SINT Pad5 (Hidden=True); SINT Pad6 (Hidden=True); SINT Pad7 (Hidden=True); SINT Pad8 (Hidden=True); SINT Pad9 (Hidden=True); SINT Pad10 (Hidden=True); SINT Pad11 (Hidden=True); SINT Pad12 (Hidden=True); SINT Pad13 (Hidden=True); SINT Pad14 (Hidden=True); SINT Pad15 (Hidden=True); SINT Pad16 (Hidden=True); SINT Pad17 (Hidden=True); SINT Pad18 (Hidden=True); SINT Pad19 (Hidden=True); SINT Pad20 (Hidden=True); SINT Pad21 (Hidden=True); SINT Pad22 (Hidden=True); SINT Pad23 (Hidden=True); SINT Pad24 (Hidden=True); SINT Pad25 (Hidden=True); SINT Pad26 (Hidden=True); SINT Pad27(Hidden=True); SINT Pad28(Hidden=True); SINT Pad29 (Hidden=True); SINT Pad30(Hidden=True); SINT Pad31 (Hidden=True); SINT Pad32 (Hidden=True); SINT Pad33(Hidden=True); SINT Pad34 (Hidden=True); SINT Pad35(Hidden=True); SINT Pad36(Hidden=True); SINT Pad37 (Hidden=True); SINT Pad38 (Hidden=True); SINT Pad39(Hidden=True); SINT Pad40(Hidden=True); DINT AlarmRelay(Radix = Binary) (Hidden = True); Bit MajorAlarmRelay AlarmRelay: 0; DINT MulticastGroupsActive (Radix = Binary); END_DATATYPE |
Provide Feedback