Device-defined data types (Stratix 5200 6 Port Managed Switch, Input Data Type)
The tables below list and describe device-defined data types for the Stratix 5200 6 Port Managed Switch, Input Data Type. These tables include information for input (as indicated by an I) and output (as indicated by an O).
Member Name | Type | Default Display Style | Valid Value |
---|---|---|---|
DINT Fault (Radix = Binary); DINT LinkStatus (Radix = Binary) (Hidden = True); | DINT | Binary | |
AnyPortConnected | BOOL | Decimal | LinkStatus:0 |
PortGi1_1Connected | BOOL | Decimal | LinkStatus:1 |
PortGi1_2Connected | BOOL | Decimal | LinkStatus:2 |
PortFa1_3Connected | BOOL | Decimal | LinkStatus:3 |
PortFa1_4Connected | BOOL | Decimal | LinkStatus:4 |
PortFa1_5Connected | BOOL | Decimal | LinkStatus:5 |
PortFa1_6Connected | BOOL | Decimal | LinkStatus:6 |
Pad1 (Hidden = True) | DINT | Decimal | |
DINT UnauthorizedDevice (Radix = Binary) (Hidden = True); | |||
AnyPortUnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:0 |
PortGi1_1UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:1 |
PortGi1_2UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:2 |
PortFa1_3UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:3 |
PortFa1_4UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:4 |
PortFa1_5UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:5 |
PortFa1_6UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:6 |
Pad2 (Hidden = True) | DINT | Decimal | |
DINT ThresholdExceeded (Radix = Binary) (Hidden = True); | |||
AnyPortThreshold | BOOL | Decimal | ThresholdExceeded:0 |
PortGi1_1Threshold | BOOL | Decimal | ThresholdExceeded:1 |
PortGi1_2Threshold | BOOL | Decimal | ThresholdExceeded:2 |
PortFa1_3Threshold | BOOL | Decimal | ThresholdExceeded:3 |
PortFa1_4Threshold | BOOL | Decimal | ThresholdExceeded:4 |
PortFa1_5Threshold | BOOL | Decimal | ThresholdExceeded:5 |
PortFa1_6Threshold | BOOL | Decimal | ThresholdExceeded:6 |
Pad3 (Hidden = True) | DINT | Decimal | |
SINT AllPortsUtilization; SINT PortGi1_1Utilization; SINT PortGi1_2Utilization; SINT PortFa1_3Utilization; SINT PortFa1_4Utilization; SINT PortFa1_5Utilization; SINT PortFa1_6Utilization; SINT PortFa1_7Utilization(Hidden=True); SINT PortFa1_8Utilization(Hidden=True); SINT PortFa1_9Utilization(Hidden=True); SINT PortFa1_10Utilization(Hidden=True); SINT PortFa1_11Utilization(Hidden=True); SINT PortFa1_12Utilization(Hidden=True); SINT PortFa1_13Utilization(Hidden=True); SINT PortFa1_14Utilization(Hidden=True); SINT PortFa1_15Utilization(Hidden=True); SINT PortFa1_16Utilization(Hidden=True); SINT PortFa1_17Utilization(Hidden=True); SINT PortFa1_18Utilization(Hidden=True); SINT PortFa1_19Utilization(Hidden=True); SINT PortFa1_20Utilization(Hidden=True); SINT PortFa1_21Utilization(Hidden=True); SINT PortFa1_22Utilization(Hidden=True); SINT PortFa1_23Utilization(Hidden=True); SINT PortFa1_24Utilization(Hidden=True); SINT PortFa1_25Utilization(Hidden=True); SINT PortFa1_26Utilization(Hidden=True); SINT Pad4 (Hidden=True); SINT Pad5 (Hidden=True); SINT Pad6 (Hidden=True); SINT Pad7 (Hidden=True); SINT Pad8 (Hidden=True); SINT Pad9 (Hidden=True); SINT Pad10 (Hidden=True); SINT Pad11 (Hidden=True); SINT Pad12 (Hidden=True); SINT Pad13 (Hidden=True); SINT Pad14 (Hidden=True); SINT Pad15 (Hidden=True); SINT Pad16 (Hidden=True); SINT Pad17 (Hidden=True); SINT Pad18 (Hidden=True); SINT Pad19 (Hidden=True); SINT Pad20 (Hidden=True); SINT Pad21 (Hidden=True); SINT Pad22 (Hidden=True); SINT Pad23 (Hidden=True); SINT Pad24 (Hidden=True); SINT Pad25 (Hidden=True); SINT Pad26 (Hidden=True); SINT Pad27(Hidden=True); SINT Pad28(Hidden=True); SINT Pad29 (Hidden=True); SINT Pad30(Hidden=True); SINT Pad31 (Hidden=True); SINT Pad32 (Hidden=True); SINT Pad33(Hidden=True); SINT Pad34 (Hidden=True); SINT Pad35(Hidden=True); SINT Pad36(Hidden=True); SINT Pad37 (Hidden=True); SINT Pad38 (Hidden=True); SINT Pad39(Hidden=True); SINT Pad40(Hidden=True); DINT AlarmRelay(Radix = Binary) (Hidden = True); Bit MajorAlarmRelay AlarmRelay: 0; DINT MulticastGroupsActive (Radix = Binary); END_DATATYPE |
Member Name | Type | Default Display Style | Valid Values |
---|---|---|---|
DINT Fault (Radix = Binary); DINT LinkStatus (Radix = Binary) (Hidden = True); | DINT | Binary | |
AnyPortConnected | BOOL | Decimal | LinkStatus:0 |
PortGi1_1Connected | BOOL | Decimal | LinkStatus:1 |
PortGi1_2Connected | BOOL | Decimal | LinkStatus:2 |
PortGi1_3Connected | BOOL | Decimal | LinkStatus:3 |
PortGi1_4Connected | BOOL | Decimal | LinkStatus:4 |
PortGi1_5Connected | BOOL | Decimal | LinkStatus:5 |
PortGi1_6Connected | BOOL | Decimal | LinkStatus:6 |
Pad1 (Hidden = True) | DINT | Decimal | |
DINT UnauthorizedDevice (Radix = Binary) (Hidden = True); | |||
AnyPortUnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:0 |
PortGi1_1UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:1 |
PortGi1_2UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:2 |
PortGi1_3UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:3 |
PortGi1_4UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:4 |
PortGi1_5UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:5 |
PortGi1_6UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:6 |
Pad2 (Hidden = True) | DINT | Decimal | |
DINT ThresholdExceeded (Radix = Binary) (Hidden = True); | |||
AnyPortThreshold | BOOL | Decimal | ThresholdExceeded:0 |
PortGi1_1Threshold | BOOL | Decimal | ThresholdExceeded:1 |
PortGi1_2Threshold | BOOL | Decimal | ThresholdExceeded:2 |
PortGi1_3Threshold | BOOL | Decimal | ThresholdExceeded:3 |
PortGi1_4Threshold | BOOL | Decimal | ThresholdExceeded:4 |
PortGi1_5Threshold | BOOL | Decimal | ThresholdExceeded:5 |
PortGi1_6Threshold | BOOL | Decimal | ThresholdExceeded:6 |
Pad3 (Hidden = True) | DINT | Decimal | |
SINT AllPortsUtilization; SINT PortGi1_1Utilization; SINT PortGi1_2Utilization; SINT PortGi1_3Utilization; SINT PortGi1_4Utilization; SINT PortGi1_5Utilization; SINT PortGi1_6Utilization; SINT PortGi1_7Utilization(Hidden=True); SINT PortGi1_8Utilization(Hidden=True); SINT PortGi1_9Utilization(Hidden=True); SINT PortGi1_10Utilization(Hidden=True); SINT PortGi1_11Utilization(Hidden=True); SINT PortGi1_12Utilization(Hidden=True); SINT PortGi1_13Utilization(Hidden=True); SINT PortGi1_14Utilization(Hidden=True); SINT PortGi1_15Utilization(Hidden=True); SINT PortGi1_16Utilization(Hidden=True); SINT PortGi1_17Utilization(Hidden=True); SINT PortGi1_18Utilization(Hidden=True); SINT PortGi1_19Utilization(Hidden=True); SINT PortGi1_20Utilization(Hidden=True); SINT PortGi1_21Utilization(Hidden=True); SINT PortGi1_22Utilization(Hidden=True); SINT PortGi1_23Utilization(Hidden=True); SINT PortGi1_24Utilization(Hidden=True); SINT PortGi1_25Utilization(Hidden=True); SINT PortGi1_26Utilization(Hidden=True); SINT Pad4 (Hidden=True); SINT Pad5 (Hidden=True); SINT Pad6 (Hidden=True); SINT Pad7 (Hidden=True); SINT Pad8 (Hidden=True); SINT Pad9 (Hidden=True); SINT Pad10 (Hidden=True); SINT Pad11 (Hidden=True); SINT Pad12 (Hidden=True); SINT Pad13 (Hidden=True); SINT Pad14 (Hidden=True); SINT Pad15 (Hidden=True); SINT Pad16 (Hidden=True); SINT Pad17 (Hidden=True); SINT Pad18 (Hidden=True); SINT Pad19 (Hidden=True); SINT Pad20 (Hidden=True); SINT Pad21 (Hidden=True); SINT Pad22 (Hidden=True); SINT Pad23 (Hidden=True); SINT Pad24 (Hidden=True); SINT Pad25 (Hidden=True); SINT Pad26 (Hidden=True); SINT Pad27(Hidden=True); SINT Pad28(Hidden=True); SINT Pad29 (Hidden=True); SINT Pad30(Hidden=True); SINT Pad31 (Hidden=True); SINT Pad32 (Hidden=True); SINT Pad33(Hidden=True); SINT Pad34 (Hidden=True); SINT Pad35(Hidden=True); SINT Pad36(Hidden=True); SINT Pad37 (Hidden=True); SINT Pad38 (Hidden=True); SINT Pad39(Hidden=True); SINT Pad40(Hidden=True); DINT AlarmRelay(Radix = Binary) (Hidden = True); Bit MajorAlarmRelay AlarmRelay: 0; DINT MulticastGroupsActive (Radix = Binary); END_DATATYPE |