Device-defined data types (Stratix 5400 12 Port GB Managed Switch)
The tables below list and describe device-defined data types for the Stratix 5400 12 Port Gigabit Managed Switch. These tables include information for input (as indicated by an I) and output (as indicated by an O).
Device-defined data type: AB:STRATIX_5400_12PORT_GB_MANAGED:I:0
Member Name | Type | Default Display Style | Valid Values |
---|---|---|---|
Fault | DINT | Binary | |
AnyPortConnected | BOOL | Decimal | LinkStatus:0 |
PortGi1_1Connected | BOOL | Decimal | LinkStatus:1 |
PortGi1_2Connected | BOOL | Decimal | LinkStatus:2 |
PortGi1_3Connected | BOOL | Decimal | LinkStatus:3 |
PortGi1_4Connected | BOOL | Decimal | LinkStatus:4 |
PortGi1_5Connected | BOOL | Decimal | LinkStatus:5 |
PortGi1_6Connected | BOOL | Decimal | LinkStatus:6 |
PortGi1_7Connected | BOOL | Decimal | LinkStatus:7 |
PortGi1_8Connected | BOOL | Decimal | LinkStatus:8 |
PortGi1_9Connected | BOOL | Decimal | LinkStatus:9 |
PortGi1_10Connected | BOOL | Decimal | LinkStatus:10 |
PortGi1_11Connected | BOOL | Decimal | LinkStatus:11 |
PortGi1_12Connected | BOOL | Decimal | LinkStatus:12 |
AnyPortUnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:0 |
PortGi1_1UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:1 |
PortGi1_2UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:2 |
PortGi1_3UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:3 |
PortGi1_4UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:4 |
PortGi1_5UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:5 |
PortGi1_6UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:6 |
PortGi1_7UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:7 |
PortGi1_8UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:8 |
PortGi1_9UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:9 |
PortGi1_10UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:10 |
PortGi1_11UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:11 |
PortGi1_12UnauthorizedDevice | BOOL | Decimal | UnauthorizedDevice:12 |
AnyPortThreshold | BOOL | Decimal | ThresholdExceeded:0 |
PortGi1_1Threshold | BOOL | Decimal | ThresholdExceeded:1 |
PortGi1_2Threshold | BOOL | Decimal | ThresholdExceeded:2 |
PortGi1_3Threshold | BOOL | Decimal | ThresholdExceeded:3 |
PortGi1_4Threshold | BOOL | Decimal | ThresholdExceeded:4 |
PortGi1_5Threshold | BOOL | Decimal | ThresholdExceeded:5 |
PortGi1_6Threshold | BOOL | Decimal | ThresholdExceeded:6 |
PortGi1_7Threshold | BOOL | Decimal | ThresholdExceeded:7 |
PortGi1_8Threshold | BOOL | Decimal | ThresholdExceeded:8 |
PortGi1_9Threshold | BOOL | Decimal | ThresholdExceeded:9 |
PortGi1_10Threshold | BOOL | Decimal | ThresholdExceeded:10 |
PortGi1_11Threshold | BOOL | Decimal | ThresholdExceeded:11 |
PortGi1_12Threshold | BOOL | Decimal | ThresholdExceeded:12 |
AllPortsUtilization | SINT | Decimal | |
PortGi1_1Utilization | SINT | Decimal | |
PortGi1_2Utilization | SINT | Decimal | |
PortGi1_3Utilization | SINT | Decimal | |
PortGi1_4Utilization | SINT | Decimal | |
PortGi1_5Utilization | SINT | Decimal | |
PortGi1_6Utilization | SINT | Decimal | |
PortGi1_7Utilization | SINT | Decimal | |
PortGi1_8Utilization | SINT | Decimal | |
PortGi1_9Utilization | SINT | Decimal | |
PortGi1_10Utilization | SINT | Decimal | |
PortGi1_11Utilization | SINT | Decimal | |
PortGi1_12Utilization | SINT | Decimal | |
MajorAlarmRelay | BOOL | Decimal | AlarmRelay:0 |
MinorAlarmRelay | BOOL | Decimal | AlarmRelay:1 |
MulticastGroupsActive | DINT | Binary |
Device-defined data type: AB:STRATIX_5400_12PORT_GB_MANAGED:O:0
This device-defined data type is created for the device when
Data Connection
is Data
.Member Name | Type | Default Display Style | Valid Values |
---|---|---|---|
AllPortsDisable | BOOL | Decimal | DisablePort:0 |
PortGi1_1Disable | BOOL | Decimal | DisablePort:1 |
PortGi1_2Disable | BOOL | Decimal | DisablePort:2 |
PortGi1_3Disable | BOOL | Decimal | DisablePort:3 |
PortGi1_4Disable | BOOL | Decimal | DisablePort:4 |
PortGi1_5Disable | BOOL | Decimal | DisablePort:5 |
PortGi1_6Disable | BOOL | Decimal | DisablePort:6 |
PortGi1_7Disable | BOOL | Decimal | DisablePort:7 |
PortGi1_8Disable | BOOL | Decimal | DisablePort:8 |
PortGi1_9Disable | BOOL | Decimal | DisablePort:9 |
PortGi1_10Disable | BOOL | Decimal | DisablePort:10 |
PortGi1_11Disable | BOOL | Decimal | DisablePort:11 |
PortGi1_12Disable | BOOL | Decimal | DisablePort:12 |