dtread(string[,format])

Returns a new date/time variable generated by reading a string. The string can be a variable, a constant, or the output of the $str function. The format may be omitted if the default parser can understand the string without it; if present, it must be surrounded by quote (") characters. The format is specified using characters such as commas, colons, hyphens, slashes, or whatever occurs in the data, combined with these key characters:
  • m
    : Month number (1-12), no leading zeros
  • mm
    : Month number (01-12), always two digits
  • mmm
    : Three letter abbreviation for month name, English only (Jan-Dec)
  • mmmm
    : Month name fully spelled out, English only
  • d
    : Day number (1-31), no leading zeros
  • dd
    : Day number (01-31), always two digits
  • y
    : Year (1-9999), no leading zeros, as many digits as needed
  • yy
    : Last two digits of year (00-99), interpreted within the range 1950-2049
  • yyyy
    : Four digit year
  • www
    : Three letter abbreviation for weekday name, English only (Sun-Sat)
  • wwww
    : Weekday name fully spelled out, English only
  • j
    : Day number in the year (1-366), no leading zeros
  • jjj
    : Day number in the year (001-366), always three digits
  • k
    : Week number (1-54), no leading zeros: Week 1 begins on January 1; the week number increments on each subsequent Sunday and is not affected by changing from one month to the next. The week number can be 54 only when a leap year begins on a Saturday.
  • kk
    : Week number (01-54), always two digits.
  • h
    : Hour (1-12 or 1-24), no leading zeros
  • hh
    : Hour (01-12 or 01-24), always two digits
  • m
    : Minute (1-59), no leading zeros
  • mm
    : Minute (01-59), always two digits
  • s
    : Second (1-59), no leading zeros
  • ss
    : Second (01-59), always two digits
  • t
    : Tenths of a second (0-9), one digit only
  • tt
    : Hundredths of a second (00-99), always two digits
  • ttt
    : Thousandths of a second (000-999), always three digits
  • a
    : a.m. and p.m. indicated by a single a or p
  • p
    : alternative for “a”
  • am
    : a.m. and p.m. indicated by the letters am or pm
  • pm
    : alternative for “am”
  • a.m.
    : a.m. and p.m. indicated by the characters “a.m.” or “p.m.”, with periods and no spaces
  • p.m.
    : alternative for “a.m.”
  • *: A single character that exists in the data and is to be ignored by the parser for the dtread transform