Set up the main window

Set up the main window

Configure the main window of your runtime application.
The main window is the basic element that contains all the graphical elements, both in
FactoryTalk Optix Studio
during
design time
and during execution of the
runtime
application.
This project contains the two graphical elements that will always be visible in the application interface: a company logo and a navigation menu.
When started at runtime, the window appears with the dimensions set in the project. When you resize the window, and the graphical elements inside reposition themselves accordingly.
This window appears.
  • MainWindow - Determine which graphical elements and information to display at runtime. For example:
    • the company logo
    • a main navigation element, such as the
      Navigation panel
      object
    • information on the connection with a PLC; for example, an LED which signals the connection status
    • contact information such as technical support or other minor information.
  • Emulator - Select
    Emulator
    to check the application operation at runtime.
    NOTE: If no active license is available, the maximum application runtime is two hours.
    .
Step #1: Set the main window dimensions
By default, the project contains the
MainWindow (type)
object which includes the main window. To customize its dimensions:
  1. In the
    Project
    panel, in
    UI
    double-click
    MainWindow (type)
    . The window appears in the editor.
  2. Set the
    Full screen
    property to
    False
    .
  3. In the
    Properties
    panel, set
    Width
    to 600 pixels and
    Height
    to 450 pixels. These are the initial window dimensions.
  4. Select in the main toolbar To save the changes,
    NOTE: Save every change to the project. Save the project at any time in the design process. If unsaved changes exist when closing FactoryTalk Optix Studio, the system prompts to save.
For more information about object sizing, see Size of the objects.
Step #2: Add and position the logo
  1. Drag the downloaded image (
    logo.png
    ) from the folder on your PC into the window in the editor: the logo appears in the editor, and in the
    Project
    panel the corresponding
    Image1
    object is created inside
    MainWindow (type)
    .
  2. To resize the logo, set these properties:
    Width
    - 200 pixels and
    Height
    -
    Auto.
    The height is automatically set using the aspect ratio of the image.
  3. To position the logo at the top right, slightly away from the window borders, set the following properties:
    • Horizontal alignment
      on
      Right
      and
      Vertical alignment
      on
      Top
      : the logo positions itself at the top right
      relative
      to the window, so it maintains its position regardless of the window size.
    • Top margin
      and
      Right margin
      at 5 pixels: regardless of the size of the window, the logo always keeps the same margin.
  4. Select to save the changes.
For more information about relative positioning of objects, see Positioning of the objects.
Step #3: Organize the navigation
To navigate between the different panels that make up the graphical interface, prepare a dedicated container, named
Navigation Panel
:
  1. Right-click
    MainWindow (type)
    , then select
    New
    >
    Containers
    >
    Navigation panel
    .
    NavigationPanel1
    appears in
    MainWindow (type)
    .
  2. In the properties, set
    Horizontal alignment
    and
    Vertical alignment
    to
    Stretch.
    The panel occupies the entire height and width of the window.
  3. To position the panel in height below the logo, set the
    Top margin
    property to 60 pixels.
  4. Select
    Save
    to save the changes.
The panel set stretches horizontally and vertically to the page size and maintains a fixed distance from the top margin, therefore from the logo
For more information about automatic object sizing, see Size of the objects.
Step #4: Check the operation at runtime
To check the operation at runtime of what we have done so far, run the application through the emulator included in FactoryTalk Optix Studio.
  1. Select
    Emulator
    in the main toolbar: after a few moments the window of the running FactoryTalk Optix Application appears.
    NOTE: If this is the first time a FactoryTalk Optix Application is run via the emulator, Windows requires a firewall rule to be configured. To proceed give access permission.
  2. To stop the application, close the window or select in FactoryTalk Optix Studio.
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.