Configure a range transitioned event

Trigger methods if the value of a variable or object property is in or out of a specific range.
  1. In
    Project view
    , select an object or a variable.
  2. In
    Properties
    , right-click a variable or a property and select
    New
    Range transitioned event
    .
    TIP: If needed, select
    Add
    Add
    to add a variable.
  3. In
    Events
    , from
    Transition
    select:
    • In (Exclusive)
    • Out (Exclusive)
    • In (Inclusive)
    • Out (Inclusive)
    Item
    Description
    Range
    Value transition
    Method execution
  4. Set the
    From
    property.
    TIP: You can enter the threshold value or add a dynamic link to the threshold value. For more information about dynamic links, see Create dynamic links.
  5. Set the
    To
    property.
    TIP: You can enter the threshold value or add a dynamic link to the threshold value. For more information about dynamic links, see Create dynamic links.
  6. Next to
    VariableTransitioned
    , select
    Add
    Add
    .
  7. Select a method:
    • For global methods, expand
      Commands
      .
    • For local methods, expand the nodes that expose methods (for example, a
      DataGrid
      node exposes a
      Refresh
      method), or expand the node related to a specific NetLogic.
  8. (optional) If the method requires arguments, expand the method and set arguments.
  9. (optional) Select additional methods.
Provide Feedback