InformationModel.MakeObject(browseName, objectTypeId)

InformationModel.MakeObject(browseName, objectTypeId)

Creates a project object of the type passed in the second argument and returns a corresponding
IUAObject
C# object type.
static IUAObject MakeObject(QualifiedName
browseName
, NodeId
objectTypeId
);

Arguments

browseName
(QualifiedName)
The
BrowseName
of the new object.
objectTypeId
(NodeId)
The
NodeID
of the type from which the new object is derived.

Returns

IUAObject
A C# object that corresponds to the project object created.

Example

The following example shows an API that creates a
NewMotor
object derived from
Motor (type)
, searched with the
Find
method, and then specified using NodeID:
var motorType = Project.Current.Find("Motor"); var mymotor = InformationModel.MakeObject("NewMotor", motorType.NodeId);
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.