- Getting started
- Creating projects
- Graphic objects
- Predefined graphic objects
- Object and variable references
- Extending projects
- NetLogic
- Tutorials
- Dynamic links tutorial
- Graphic objects tutorial
- NetLogic tutorial
- OPC UA tutorial
S7 TIA PROFINET driver
Observe these guidelines when working with the S7 TIA PROFINET driver.
Supported controllers
The driver supports these controller families:
- Siemens® S7-1200 Series
- Siemens® S7-1500 Series
Controller tags import
The driver supports only optimized structures.
You can import tags in these modes:
- Online mode
- Use online mode to import tags directly from the controller at design time or runtime.IMPORTANT:Before importing tags from a controller:
- SetAccess levelto aFull accessoption.
- If applicable, disable theOnly allow secure PG/PC and HMI communicationoption.
For more information, refer to the product documentation. - Offline mode
- Use offline mode to import tags from these project files:ap13,ap14,ap15,ap16,ap17,ap18,ap19.IMPORTANT:Before importing tags from a project file:
- Ensure that the project file is compiled with theOptimized block accessproperty enabled.
- If your project has multiple programs, choose the program from which you want to import the tags.
- If the controller communication is authenticated with certificates:
- From TIA Portal®, export theDERcertificate and then paste the certificate into theFTOptixApplication/ProjectFiles/PKI/Own/Certs/folder of theFactoryTalk Optixproject.
- InFactoryTalk Optix Studio, in theController certificate fileproperty of theS7TIAPROFINETStationobject, select the exported certificate.#
For more information, refer to the product documentation.
Data types
The driver supports these data types:
Controller data type | FactoryTalk Optix data type | Length | Notes |
---|---|---|---|
BOOL | BOOL | 1 BIT | |
BYTE | BYTE | 1 BYTE | |
WORD | UINT16 | 2 BYTES | |
DWORD | UINT32 | 4 BYTES | |
LWORD | UINT64 | 8 BYTES | |
SINT | SBYTE | 1 BYTES | |
INT | INT16 | 2 BYTES | |
DINT | INT32 | 2 BYTES | |
USINT | BYTE | 1 BYTE | |
UINT | UINT16 | 2 BYTES | |
UDINT | UINT32 | 4 BYTES | |
LINT | INT64 | 4 BYTES | |
ULINT | UINT64 | 8 BYTES | |
REAL | FLOAT | 4 BYTES | |
LREAL | DOUBLE | 8 BYTES | |
S5TIME | UINT32 | 2 BYTES | For more information about the time base, refer to the product documentation. |
TIME | DURATION | 4 BYTES | Rockwell Automation recommends using the Duration object, which allows you to set and view the duration of a tag. |
LTIME | DURATION | 8 BYTES | |
DATE | DATE | 2 BYTES | Rockwell Automation recommends using the Date and time object, which allows you to set and view date and time data. |
TIME_OF_DAY(TOD) | UTC TIME | 4 BYTES | |
LTIME_OF_DAY(LTOD) | UTC TIME | 8 BYTES | |
DATE_AND_TIME(DT) | DATE TIME | 8 BYTES | |
LDT | DATE TIME | 8 BYTES | |
DTL | Struct | 12 BYTES | |
CHAR | SByte | 1 BYTES | |
WCHAR | UINT16 | 2 BYTES | |
STRING | STRING-MAX254 | LENGTH +2 BYTES | An operand of the STRING data type occupies two bytes more than the specified maximum length in the memory. For more information, refer to the product documentation. |
WSTRING | STRING-MAX 254 | LENGTH+2 WORDS | An operand of the WSTRING data type occupies two WORDs more in the memory than the specified maximum length. For more information, refer to the product documentation. |
STRUCT | STRUCT | ||
Timer | UINT32 | 4 BYTES | |
COUNTER | UINT16 | 2 BYTES | |
IEC_Timer | Struct | 16 BYTES | |
IEC_LTimer | Struct | 32 BYTES | |
IEC_SCounter | Struct | 3 BYTES | |
IEC_USCounter | Struct | 3 BYTES | |
IEC_Counter | Struct | 6 BYTES | |
IEC_UCounter | Struct | 6 BYTES | |
IEC_DCounter | Struct | 12 BYTES | |
IEC_UDCounter | Struct | 12 BYTES | |
IEC_LCounter | Struct | 24 BYTES | |
IEC_ULCounter | Struct | 24 BYTES | |
ARRAY 1 dimensional | Type [dimension] | ||
ARRAY 2 dimensional | Type [1st dimension, 2nd dimension] | ||
ARRAY 3 dimensional | Type [1st dimension ,2nd dimension, 3rd dimension] |
s7 tia profinet
s7 tia profinet driver
Provide Feedback