Corrected anomalies in this release
The list identifies the anomalies corrected in
FactoryTalk Optix
1.5.x.Broken references when importing widgets from the template library [3634901]
NetLogic defined on a child of a widget will not be imported from the template library when it contains the same name as other NetLogic used within the project resulting in broken NetLogic references.
This anomaly corrected in version 1.5.0.
This anomaly first identified in version 1.4.0.
Trend range update may affect result table [3612644]
Updating the
Ranges
tab in the Advanced Trend widget may affect the result table. This anomaly corrected in version 1.5.0.
This anomaly first identified in version 1.4.0.
Non-variable event field causes runtime error [3545147]
A discrepancy in event argument handling causes the return of non-variable nodes and displays the error "The event field resolves into a non-variable”.
This anomaly corrected in version 1.5.0.
This anomaly first identified in version 1.4.0.
Image may not refresh on web presentation engine [3478736]
The ImageRefresher script does not work as expected using the web presentation engine. To display the image correctly, the web browser needs to be refreshed manually.
This anomaly corrected in version 1.5.0.
This anomaly first identified in version 1.4.0
Min and Max values do not display for Date Time and Duration types [3370306]
FactoryTalk Optix
does not support Min and Max values for Date Time and Duration types. Do not import Min or Max values for these types. This anomaly corrected in version 1.5.0.
This anomaly first identified in version 1.4.0
Runtime tool cannot deploy to second computer if the computer name contains special characters [3303008]
Do not use Chinese or European special characters in computer names.
This anomaly corrected in version 1.5.0.
This anomaly first identified in version 1.4.0.
Unable to debug DesignTime NetLogic from Visual Studio Code [3511011]
The C# extension for Visual Studio Code was updated and some issues were detected with the recent versions. To debug design time NetLogic from Visual Studio Code, revert the C# extension to version 2.4.4 or earlier.
This anomaly corrected in version 1.5.0.
This anomaly first identified in version 1.3.1.
Unable to compile NetSolution [3327229]
NetSolution does not compile without internet access. Establish an internet connection to retrieve the required components.
This anomaly corrected in version 1.5.0.
This anomaly first identified in version 1.3.0.
Renaming a user-defined library using OneDrive may result in synchronization errors [2348900]
OneDrive is not recommended for storing user-defined libraries and may result in synchronization errors and duplicate files when renaming libraries. If attempting to use OneDrive to rename a library, unlink OneDrive when renaming the library. To unlink OneDrive, see Turn off, disable, or uninstall OneDrive.
This anomaly corrected in version 1.5.0.
This anomaly first identified in version 1.3.0.
Special characters not always supported [2123530]
Special characters are supported in PDF filenames and FTP Server usernames, but are not supported when using the Microsoft Pinyin input method on the device.
This anomaly corrected in version 1.5.0.
This anomaly first identified in version 1.2.0.