Boolean NOT (BNOT)

Boolean NOT (BNOT)

This information applies to the CompactLogix 5370, ControlLogix 5570, Compact GuardLogix 5370, GuardLogix 5570, Compact GuardLogix 5380, CompactLogix 5380, CompactLogix 5480, ControlLogix 5580, and GuardLogix 5580 controllers.
The BNOT instruction complements a Boolean input. To perform a bitwise NOT, refer to
Bitwise Not (NOT)
.
Available Languages
Ladder Diagram
This instruction is not available in ladder diagram.
Function Block Diagram
Function Block Diagram supports these elements:
FBD Block
BNOT_FBD_avail_v31
FBD Function
TIP:
FBD Function is applicable to CompactLogix 5380, CompactLogix 5480, ControlLogix 5580, Compact GuardLogix 5380, and GuardLogix 5580 controllers only.
BNOT_f_avail lang
Structured Text
This instruction is not available in structured text.
Operands
Function Block Diagram
FBD Block
Operand
Data Type
Format
Description
BNOT tag
FBD_BOOLEAN_NOT
structure
BNOT structure
FBD_BOOLEAN_NOT Structure
Input Members
Data Type
Description
EnableIn
BOOL
Enable input. If cleared, the instruction does not execute and outputs are not updated.
Default is set.
In
BOOL
Input to the instruction.
Set to 1 on first download
Output Members
Data Type
Description
EnableOut
BOOL
Indicates if instruction is enabled.
Out
BOOL
The output of the instruction.
FBD Function
TIP:
FBD Function is applicable to CompactLogix 5380, CompactLogix 5480, ControlLogix 5580, Compact GuardLogix 5380, and GuardLogix 5580 controllers only.
Input Operands (Left Pins)
Data Type
CompactLogix 5380, CompactLogix 5480, ControlLogix 5580, Compact GuardLogix 5380, and GuardLogix 5580 controllers
Description
In
BOOL
Input to the instruction.
Output Operand (Right Pin)
Data Type
CompactLogix 5380, CompactLogix 5480, ControlLogix 5580, Compact GuardLogix 5380, and GuardLogix 5580 controllers
Description
Out
BOOL
The output of the instruction.
Operation
The BNOT instruction complements a Boolean input.
Out = NOT In
Affects Math Status Flags
No
Major/Minor Faults
None specific to this instruction.
Execution
Function Block Diagram
FBD Block
Condition/State
Action Taken
Prescan
EnableIn and EnableOut bits are cleared to false.
Tag.EnableIn is false
EnableIn and EnableOut bits are cleared to false.
Tag.EnableIn is true
EnableIn and EnableOut bits are set to true.
The instruction executes as described in the Operation section.
Instruction first run
N/A
Instruction first scan
N/A
Postscan
EnableIn and EnableOut bits are cleared to false.
FBD Functions
TIP:
FBD Function is applicable to CompactLogix 5380, CompactLogix 5480, ControlLogix 5580, Compact GuardLogix 5380, and GuardLogix 5580 controllers only.
Condition/State
Action Taken
Prescan
N/A
Normal Scan
The instruction executes as described in the Operation section.
Instruction first run
N/A
Instruction first scan
N/A
Postscan
N/A
Example
Function Block Diagram
FBD Block
In this example, bool_in1 is copied into BNOT_02.In, the result of the complement of BNOT_02.In is placed into BNOT_02.Out and BNOT_02.Out is copied into value_result_not.
If bool_in1 is:
Then value_result_not is:
0
1
1
0
BNOT_FBD_ex_v31
FBD Function
In this example, the result of the complement of bool_in1 is placed in value_result_not.
BNOT_f_example
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.