Module Data Types - 1794-OE8H, 1797-OE8H

The table below lists and describes the module-defined data types for the 1797-OE8 module. It includes information for input (as indicated by an "I"), output (as indicated by an "O"), and configuration (as indicated by a "C").
TIP:
FLEX Ex I/O is based on 16-bit INTs and not 32-bit DINTs. Using 16-bit INTs in instructions that are optimized for 32-bit DINTs may decrease performance with certain instructions.
IMPORTANT:
Some of the configuration information for this module is located in the output module-defined data type and is different than that on an RSLogix 5 system. Since this information is exposed differently in RSLogix 5 and RSLogix 5000 systems, you must remember to verify the configuration information in the output module-defined data type on a RSLogix 5000 system.
In addition, an output module is configured by a controller that establishes a connection as an owner; however, only one owner connection is allowed for output modules. If another controller attempts to establish an owner connection, the connection attempt is rejected.
connection
The link between networks and devices.
Module-defined Data Type:AB:1797_OE8_HART:I:0
Member Name
Type
Default
Display Style
Description
Fault
DINT
Binary
Fault - Used for Input Data Validation0 = Valid Data1 = Invalid Data - if the connection to the module has been lost, or if the module has a severe hardware fault, the lower 8 members are set to 1.
Alarms
INT
Binary
Alarm data for the DiagnosticStatus members 0 through 3 below. The remaining members are reserved.
DiagnosticStatus0
DiagnosticStatus1
DiagnosticStatus2
DiagnosticStatus3
BOOL
Decimal
These settings (0 through 3) represent module configuration and/or hardware errors.
HARTRebuild
BOOL
Decimal
Ch0FaultAlarm
Ch1FaultAlarm
Ch2FaultAlarm
Ch3FaultAlarm
Ch4FaultAlarm
Ch5FaultAlarm
Ch6FaultAlarm
Ch7FaultAlarm
BOOL
Decimal
These members are used to determine if a fault has occurred on a channel.
Reserved
INT
Binary
StatusHARTFailure
SINT
Binary
StatusHARTReadBack
SINT
Binary
StatusHARTComm
SINT
Binary
StatusHARTTransmitList
SINT
Binary
Module-defined Data Type:AB:1797_OE8_HART:O:0
Member Name
Type
Default
Display Style
Description
DigitalData
SINT
Binary
These 8 members individually represent the Digital output data for each channel.
DigOutCh0
DigOutCh1
DigOutCh2
DigOutCh3
DigOutCh4
DigOutCh5
DigOutCh6
DigOutCh7
BOOL
Decimal
OutputControl
SINT
Binary
This data type represents the Output Control for the output data. FaultReset and OuputEnable are included members while the remaining 6 members are reserved.
Ch0AnalogData
Ch1AnalogData
Ch2AnalogData
Ch3AnalogData
Ch4AnalogData
Ch5AnalogData
Ch6AnalogData
Ch7AnalogData
INT
Decimal
This member represents the Analog output data for the respective channel.
Module-defined Data Type:AB:1797_OE8_HART:C:0
Member Name
Type
Default
Display Style
Description
Config1
INT
Binary
Configuration information.
Ch0_1DataFormat0
BOOL
Decimal
Analog Mode Data Format value for channel pair 0 and 1.
Ch0_1DataFormat1
BOOL
Decimal
Analog Mode Data Format value for channel pair 0 and 1.
Ch0_1DataFormat2
BOOL
Decimal
Analog Mode Data Format value for channel pair 0 and 1.
Ch0_1DataFormat3
BOOL
Decimal
Analog Mode Data Format value for channel pair 0 and 1.
Ch2_3DataFormat0
BOOL
Decimal
Analog Mode Data Format value for channel pair 2 and 3.
Ch2_3DataFormat1
BOOL
Decimal
Analog Mode Data Format value for channel pair 2 and 3.
Ch2_3DataFormat2
BOOL
Decimal
Analog Mode Data Format value for channel pair 2 and 3.
Ch2_3DataFormat3
BOOL
Decimal
Analog Mode Data Format value for channel pair 2 and 3.
Ch0_1AnalogSSFault0
BOOL
Decimal
Internal Safe State value for analog channel 0-1.
Ch0_1AnalogSSFault1
BOOL
Decimal
Internal Safe State value for analog channel 0-1.
Ch2_3AnalogSSFault0
BOOL
Decimal
Internal Safe State value for analog channel 2-3.
Ch2_3AnalogSSFault1
BOOL
Decimal
Internal Safe State value for analog channel 2-3.
Ch0_1FaultAlarm
BOOL
Decimal
Used to determine if fault detection on the module is enabled for this channel pair.
Ch2_3FaultAlarm
BOOL
Decimal
Used to determine if fault detection on the module is enabled for this channel pair.
LocalFaultMode
BOOL
Decimal
Determines whether the fault conditions are latched or retry.
Config2
INT
Binary
Configuration information.
Ch4_5DataFormat0
BOOL
Decimal
Analog Mode Data Format value for channel pair 4-5.
Ch4_5DataFormat1
BOOL
Decimal
Analog Mode Data Format value for channel pair 4-5.
Ch4_5DataFormat2
BOOL
Decimal
Analog Mode Data Format value for channel pair 4-5.
Ch4_5DataFormat3
BOOL
Decimal
Analog Mode Data Format value for channel pair 4-5.
Ch6_7DataFormat0
BOOL
Decimal
Analog Mode Data Format value for channel pair 6-7.
Ch6_7DataFormat1
BOOL
Decimal
Analog Mode Data Format value for channel pair 6-7.
Ch6_7DataFormat2
BOOL
Decimal
Analog Mode Data Format value for channel pair 6-7.
Ch6_7DataFormat3
BOOL
Decimal
Analog Mode Data Format value for channel pair 6-7.
Ch4_5AnalogSSFault0
BOOL
Decimal
Internal Safe State value for analog channel 4-5.
Ch4_5AnalogSSFault1
BOOL
Decimal
Internal Safe State value for analog channel 4-5.
Ch6_7AnalogSSFault0
BOOL
Decimal
Internal Safe State value for analog channel 6-7.
Ch6_7AnalogSSFault1
BOOL
Decimal
Internal Safe State value for analog channel 6-7.
Ch4_5FaultAlarm
BOOL
Decimal
Used to determine if fault detection on the module is enabled for this channel pair.
Ch6_7FaultAlarm
BOOL
Decimal
Used to determine if fault detection on the module is enabled for this channel pair.
Ch0_3FaultMode
BOOL
Decimal
Fault Detection for channels 0-1.
Ch4_7FaultMode
BOOL
Decimal
Fault Detection for channels 2-3.
Config3
INT
Binary
Configuration information.
Ch0AnalogDigitalMode
BOOL
Decimal
Output Mode for channel 0.
Ch1AnalogDigitalMode
BOOL
Decimal
Output Mode for channel 1.
Ch2AnalogDigitalMode
BOOL
Decimal
Output Mode for channel 2.
Ch3AnalogDigitalMode
BOOL
Decimal
Output Mode for channel 3.
Ch4AnalogDigitalMode
BOOL
Decimal
Output Mode for channel 4.
Ch5AnalogDigitalMode
BOOL
Decimal
Output Mode for channel 5.
Ch6AnalogDigitalMode
BOOL
Decimal
Output Mode for channel 6.
Ch7AnalogDigitalMode
BOOL
Decimal
Output Mode for channel 7.
Ch0DigitalSSFault
BOOL
Decimal
Internal Safe State value for Digital channel 0.
Ch1DigitalSSFault
BOOL
Decimal
Internal Safe State value for Digital channel 1.
Ch2DigitalSSFault
BOOL
Decimal
Internal Safe State value for Digital channel 2.
Ch3DigitalSSFault
BOOL
Decimal
Internal Safe State value for Digital channel 3.
Ch4DigitalSSFault
BOOL
Decimal
Internal Safe State value for Digital channel 4.
Ch5DigitalSSFault
BOOL
Decimal
Internal Safe State value for Digital channel 5.
Ch6DigitalSSFault
BOOL
Decimal
Internal Safe State value for Digital channel 6.
Ch7DigitalSSFault
BOOL
Decimal
Internal Safe State value for Digital channel 7.
EDTCommandData
SINT
Decimal
Extended data table command response data settings-these echo the EDT response data written to the module during calibration of the channels.
EDTCommand
SINT
Decimal
Extended data table response settings-these echo the EDT response data written to the module during calibration of the channels.
CommandFlag
BOOL
Decimal
Used to determine whether the EDTResponse command is enabled.
SSDigitalData
SINT
Binary
These members represent the Digital Safe State data.
SSOutputControl
SINT
Binary
These 8 members represent the Output Control for the Safe State data. The two members SSFaultReset and SSOutputEnable only are used. The remaining six members are reserved.
SSFaultReset
BOOL
Decimal
This member resets any fault conditions.
SSOutputEnable
BOOL
Decimal
This member enables the outputs for the channels.
SSCh0AnalogData
INT
Decimal
Internal Safe State data for Analog channel 0.
SSCh1AnalogData
INT
Decimal
Internal Safe State data for Analog channel 1.
SSCh2AnalogData
INT
Decimal
Internal Safe State data for Analog channel 2.
SSCh3AnalogData
INT
Decimal
Internal Safe State data for Analog channel 3.
SSCh4AnalogData
INT
Decimal
Internal Safe State data for Analog channel 4.
SSCh5AnalogData
INT
Decimal
Internal Safe State data for Analog channel 5.
SSCh6AnalogData
INT
Decimal
Internal Safe State data for Analog channel 6.
SSCh7AnalogData
INT
Decimal
Internal Safe State data for Analog channel 7.
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.