Module-defined Data Types (1756-DMF30)

Module-defined data type names vary for each module depending on the Communication Format you choose when you create a module. The table below lists and describes the module-defined data types created for the 1756-DMF30 module according to the Communication Format chosen. It includes information for input (as indicated by an "I") and output (as indicated by an "O").
Module-defined Data Type: AB:DMF30_GENERIC:I:0
Comm Format: User-defined Control
Member Name
Bit in
Previous Word
Data Type
Default Display Style
Drive Parameter
Description
LogicStatus
DINT
Binary
155
Logic Status
Enabled
0*
BOOL
Decimal
155.0
Enabled
Running
1*
BOOL
Decimal
155.1
Running
Faulted
7*
BOOL
Decimal
155.7
Faulted
Alarm
8*
BOOL
Decimal
155.8
Alarm
FlashMode
9*
BOOL
Decimal
155.9
Flash Mode
RunReady
10
BOOL
Decimal
155.10
Run Ready
MCEnAck
18
BOOL
Decimal
155.18
MC En Ack
MCCommis
19
BOOL
Decimal
155.19
MC Commis
SpdCommis
20
BOOL
Decimal
155.20
Spd Commis
CommandRun
26
BOOL
Decimal
155.26
Command Run
FieldCurrOn
30
BOOL
Decimal
155.30
FieldCurr On
UserDefinedRealData
REAL[12]
Float
User-defined
User-defined Real Data
UserDefinedIntegerData
DINT[3]
Decimal
User-defined
User-defined Integer Data
* Location of these bits are fixed for DPI.
Module-defined Data Type: AB:DMF30_GENERIC:O:0
Comm Format: User-defined Control
Member Name
Bit in Previous Word
Data Type
Default Display Style
Drive Parameter
Description
LogicCommand
DINT
Binary
151
Logic Command
MCAtuneEn
4
BOOL
Decimal
151.4
MC Atune En
NormalStop
16
BOOL
Decimal
*Logic Parser
Normal Stop
Start
17
BOOL
Decimal
*Logic Parser
Start
ClearFault
19
BOOL
Decimal
*Logic Parser
Clear Fault
FieldEn
30
BOOL
Decimal
*Logic Parser
Field En
UserDefinedRealData
REAL[12]
Float
User-defined
User-defined Real Data
UserDefinedIntegerData
DINT[3]
Decimal
User-defined
User-defined Integer Data
* The output from the Logic Parser is mapped to parameter 152, bits 16-31.
Module-defined Data Type: AB: DMF30_CUSTOMUSER_DEFINED:I:0
Comm Format: Custom User-defined Control
Member Name
Bit in
Previous Word
Data Type
Default Display Style
Drive Parameter
Description
LogicStatus
DINT
Binary
Logic Status
UserDefinedRealData
REAL[8]
Float
User-defined
User-defined Real Data
UserDefinedIntegerData
DINT[7]
Decimal
User-defined
User-defined Integer Data
Module-defined Data Type: AB: DMF30_CUSTOMUSER_DEFINED:O:0
Comm Format: Custom User-defined Control
Member Name
Bit in Previous Word
Data Type
Default Display Style
Drive Parameter
Description
LogicCommand
DINT
Binary
Logic Command
UserDefinedRealData
REAL[8]
Float
User-defined
User-defined Real Data
UserDefinedIntegerData
DINT[7]
Decimal
User-defined
User-defined Integer Data
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.