Module-defined Data Types (WebPak 3000)

The tables below list and describe the Input and Output module-defined data types for this module.
Module-defined Data Type: REL:WebPak3000_DC_Drive:I:0
Member Name
Bit in Previous Word
Data Type
Default Display Style
DPI Description
ConnectionStatus
DINT
Binary
Logic Status
InputsValid
DINT
Binary
Inputs Valid
DriveStatus1
INT
Binary
Drive Status 1
DriveReady
0
BOOL
Decimal
Drive Ready
DriveRunning
1
BOOL
Decimal
Drive Running
FaultActive
2
BOOL
Decimal
Fault Active
JoggingForward
3
BOOL
Decimal
Jogging Forward
JoggingReverse
4
BOOL
Decimal
Jogging Reverse
UnderWindActive
5
BOOL
Decimal
Under Wind Active
StopInProgress
6
BOOL
Decimal
Stop In Progress
TensionOnActive
7
BOOL
Decimal
Tension On Active
StallTensionActive
8
BOOL
Decimal
Stall Tension Active
CurrentMemoryActive
9
BOOL
Decimal
Current Memory Active
CurrentLimit
10
BOOL
Decimal
Current Limit
AlarmActive
11
BOOL
Decimal
Alarm Active
CurrentSpeedActive
12
BOOL
Decimal
Current Speed Active
ParameterProcessError
13
BOOL
Decimal
Parameter Process Error
LevelDetect1Output
14
BOOL
Decimal
Level Detect 1 Output
LevelDetect2Output
15
BOOL
Decimal
Level Detect 2 Output
SpeedFeedback
INT
Decimal
Speed Feedback
CurrentFeedback
INT
Decimal
Current Feedback
NetworkOutputRegister1
INT
Decimal
Network Output Register 1
NetworkOutputRegister2
INT
Decimal
Network Output Register 2
NetworkOutputRegister3
INT
Decimal
Network Output Register 3
UserDefinedData
DINT[8]
Decimal
User-defined Data
Module-defined Data Type: REL:WebPak3000_DC_Drive:O:0
Member Name
Bit in Previous Word
Data Type
Default Display Style
DPI Description
DriveControl
INT
Binary
Drive Control
SectionRun
0
BOOL
Decimal
Section Run
SectionStop
1
BOOL
Decimal
Section Stop
FaultReset
2
BOOL
Decimal
Fault Reset
JogForward
3
BOOL
Decimal
Jog Forward
JogReverse
4
BOOL
Decimal
Jog Reverse
Underwind
5
BOOL
Decimal
Under wind
SlackTakeUp
7
BOOL
Decimal
Slack Take Up
TensionOn
8
BOOL
Decimal
Tension On
DiameterReset
9
BOOL
Decimal
Diameter Reset
CurrentMemory
10
BOOL
Decimal
Current Memory
MemorySave
11
BOOL
Decimal
Memory Save
CurrentSpeed
12
BOOL
Decimal
Current Speed
DiameterSelect_A
13
BOOL
Decimal
Diameter Select A
DiameterSelect_B
14
BOOL
Decimal
Diameter Select B
SpeedTorqueReference
INT
Decimal
Speed Torque Reference
NetworkInputRegister1
INT
Decimal
Network Input Register 1
NetworkInputRegister2
INT
Decimal
Network Input Register 2
NetworkInputRegister3
INT
Decimal
Network Input Register 3
Field Reference
INT
Decimal
Field Reference
UserDefinedData
DINT[8]
Decimal
User-defined Data
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.