Commanding and Running Equipment Sequences
The right to command an Equipment Sequence or an Equipment Phase is granted through ownership.
Both
Equipment Sequence
s and Equipment Phase
s must be owned to be commanded. The ownership commands are
Attach (SATT) and Detach (SDET).Internal sequencers (programs), external sequencers (
FactoryTalk Batch
), and operators always use
an Attach instruction to command an Equipment Sequence
. Logix Designer
always uses an
Override instruction to command an Equipment Sequence
. A program might successfully attach an
Equipment Sequence
but be unable to command it because Logix Designer
has overridden ownership.Once ownership is taken, steps and transitions can be commanded and