1762-OF4
MicroLogix 4 Point Analog Output Module
Product at a glance
Product at a glance
| analog output modules |
4 Channel Analog Output Module
|
|---|---|
| Class |
Progmable Logic Controller Module
|
| Current Range |
4-20
|
| Depth |
87
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Module Interfaces |
Analog output
|
| Number Of Channels |
4 point
|
| Output |
4 Point, ±10V, 4-20 mA
|
| Temperature Rating |
-20…65 °C (-4…149 °F)
|
| Resolution of the analogue outputs |
12 bit
|
|---|---|
| Input, current |
True
|
| Input, voltage |
True
|
| Input, resistor |
False
|
| Input, resistance thermometer |
False
|
| Input, thermocouple |
False
|
| Input signal, configurable |
True
|
| Output, current |
True
|
| Output, voltage |
True
|
| Output signal configurable |
True
|
| Analogue inputs configurable |
False
|
| Analogue outputs configurable |
True
|
| Type of electric connection |
Screw connection
|
| Fast transient burst |
IEC1000-4-4: 2kV @ 5kHz
|
| Conducted immunity |
10V @ 0.15...80MHz
|
| Radiated immunity |
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Suitable for safety functions |
False
|
| Surge immunity |
IEC1000-4-5: 1kV galvanic gun
|
| Module power LED |
On: indicates power is applied
|
| Operating temperature |
-20 °C
|
|---|---|
| ESD immunity |
EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect
|
| Operating altitude |
2000 m
|
| Storage temperature |
-40 °C
|
| Operating humidity |
5...95% noncondensing
|
| Load range on voltage output |
>1KΩ
|
|---|---|
| Output update time |
Typical: 2.5 ms
|
| Number of outputs |
4 single-ended (unipolar)
|
| D/A converter type |
R-2R ladder voltage switching
|
| Non-linearity |
< ±0.59% (in % full scale)
|
| Typical overall accuracy |
±1.17% full scale @ -20...65 °C (Only applicable to Series B I/O modules.)
|
| Reactive load, voltage output |
<1 µF
|
| Reactive load, current output |
<0.1 mH
|
| Output protection |
-32 mA
|
| Open and short-circuit protection |
Continuous
|
| Resistive load on current output |
0...500 Ω (includes wire resistance)
|
| Output ripple range |
<±0.1% @ 0...500Hz (referred to output range)
|
| Analog normal operating range |
Voltage: 0...10V DC
|
|---|---|
| Bus current draw, max |
40mA @ 5V DC, 165mA @ 24V DC
|
| Full scale analog ranges |
Voltage: 0...10.5V DC, Current: 0...21 mA
|
| Repeatability |
-0.12 to 0.12%
|
| Input and output group to system isolation |
30V AC/30V DC rated working voltage (IEC Class 2 reinforced insulation) type test: 500V AC or 707V DC @ 1min
|
| Height |
90 mm
|
|---|---|
| Width |
40 mm
|
| Depth |
87 mm
|
| Recommended cable |
Belden 8761 (shielded), (For 1762-IT4, shielded thermocouple extension wire for the specific type of thermocouple you are using. Follow thermocouple manufacturer’s recommendations.)
|
| Weight |
Shipping: 235 g (0.517 lbs.) approximately (with cartoon)
|
|---|---|
| Vibration |
Operating: 5 g @ 10...500 Hz, 0.030 in. max. peak-to-peak
|
| Shock |
Operating: 30 g
|
| Hazardous environment class |
Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
|---|---|
| Radiated and conducted emissions |
EN50081-2: Class A
|
| Drawings | |
|---|---|
| Product Drawing | Drawing (DWG) |
| Drawings |
|---|
| Product Drawing Drawing (DWG) |
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
| Type | Resource | Publication |
|---|---|---|
| General | Selection Guide | 1761-SG001 |
| General | Product Cutsheet | -- |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
- UL Listed
- UL Listed Hazardous
This product was certified with the above certifications as of 2025-07-20. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
| analog output modules |
4 Channel Analog Output Module
|
|---|---|
| Class |
Progmable Logic Controller Module
|
| Current Range |
4-20
|
| Depth |
87
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Module Interfaces |
Analog output
|
| Number Of Channels |
4 point
|
| Output |
4 Point, ±10V, 4-20 mA
|
| Temperature Rating |
-20…65 °C (-4…149 °F)
|
| Resolution of the analogue outputs |
12 bit
|
|---|---|
| Input, current |
True
|
| Input, voltage |
True
|
| Input, resistor |
False
|
| Input, resistance thermometer |
False
|
| Input, thermocouple |
False
|
| Input signal, configurable |
True
|
| Output, current |
True
|
| Output, voltage |
True
|
| Output signal configurable |
True
|
| Analogue inputs configurable |
False
|
| Analogue outputs configurable |
True
|
| Type of electric connection |
Screw connection
|
| Fast transient burst |
IEC1000-4-4: 2kV @ 5kHz
|
| Conducted immunity |
10V @ 0.15...80MHz
|
| Radiated immunity |
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Suitable for safety functions |
False
|
| Surge immunity |
IEC1000-4-5: 1kV galvanic gun
|
| Module power LED |
On: indicates power is applied
|
| Operating temperature |
-20 °C
|
|---|---|
| ESD immunity |
EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect
|
| Operating altitude |
2000 m
|
| Storage temperature |
-40 °C
|
| Operating humidity |
5...95% noncondensing
|
| Load range on voltage output |
>1KΩ
|
|---|---|
| Output update time |
Typical: 2.5 ms
|
| Number of outputs |
4 single-ended (unipolar)
|
| D/A converter type |
R-2R ladder voltage switching
|
| Non-linearity |
< ±0.59% (in % full scale)
|
| Typical overall accuracy |
±1.17% full scale @ -20...65 °C (Only applicable to Series B I/O modules.)
|
| Reactive load, voltage output |
<1 µF
|
| Reactive load, current output |
<0.1 mH
|
| Output protection |
-32 mA
|
| Open and short-circuit protection |
Continuous
|
| Resistive load on current output |
0...500 Ω (includes wire resistance)
|
| Output ripple range |
<±0.1% @ 0...500Hz (referred to output range)
|
| Analog normal operating range |
Voltage: 0...10V DC
|
|---|---|
| Bus current draw, max |
40mA @ 5V DC, 165mA @ 24V DC
|
| Full scale analog ranges |
Voltage: 0...10.5V DC, Current: 0...21 mA
|
| Repeatability |
-0.12 to 0.12%
|
| Input and output group to system isolation |
30V AC/30V DC rated working voltage (IEC Class 2 reinforced insulation) type test: 500V AC or 707V DC @ 1min
|
| Height |
90 mm
|
|---|---|
| Width |
40 mm
|
| Depth |
87 mm
|
| Recommended cable |
Belden 8761 (shielded), (For 1762-IT4, shielded thermocouple extension wire for the specific type of thermocouple you are using. Follow thermocouple manufacturer’s recommendations.)
|
| Weight |
Shipping: 235 g (0.517 lbs.) approximately (with cartoon)
|
|---|---|
| Vibration |
Operating: 5 g @ 10...500 Hz, 0.030 in. max. peak-to-peak
|
| Shock |
Operating: 30 g
|
| Hazardous environment class |
Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
|---|---|
| Radiated and conducted emissions |
EN50081-2: Class A
|
Drawings
| Drawings | |
|---|---|
| Product Drawing | Drawing (DWG) |
| Drawings |
|---|
| Product Drawing Drawing (DWG) |
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
Documents
|
Selection Guide
General
1761-SG001 |
|
Product Cutsheet
General
-- |
| Type | Resource | Publication |
|---|---|---|
| General | Selection Guide | 1761-SG001 |
| General | Product Cutsheet | -- |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Certifications
- UL Listed
- UL Listed Hazardous
This product was certified with the above certifications as of 2025-07-20. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Loading
Copyright ©2026 Rockwell Automation, Inc.