FactoryTalk® Service Platform Elevated Privileges Vulnerability Through Web Service Functionality

Severity:
Critical
Advisory ID:
SD1662
게시한 날짜:
February 14, 2024
최근 업데이트:
December 04, 2024
Revision Number:
1.0
Known Exploited Vulnerability (KEV):
아니요
Corrected:
아니요
Workaround:
아니요
CVE IDs
CVE-2024-21915
파일(다운로드)
The following link(s) provide the security advisory in Vulnerability Exploitability Exchange format:
CVE-2024-21915
요약
FactoryTalk® Service Platform Elevated Privileges Vulnerability Through Web Service Functionality

Published Date: February 15, 2024
Last updated:  February 15, 2024
Revision Number: 1.0
CVSS Score: 9.0/10

The security of our products is important to us as your chosen industrial automation supplier.  This vulnerability was found internally during routine testing and is being reported based on our commitment to customer transparency.

AFFECTED PRODUCTS AND SOLUTION

Affected Product

First Known in software version

Corrected in software version

FactoryTalk® Service Platform

             <v2.74

Update to V2.74 or later


VULNERABILITY DETAILS

Rockwell Automation used version 3.1 of the CVSS scoring system to assess the following vulnerabilities.

CVE-2024-21915 IMPACT

A privilege escalation vulnerability exists in FactoryTalk® Service Platform (FTSP). If exploited, a malicious user with basic user group privileges could potentially sign into the software and receive FTSP Administrator Group privileges. A threat actor could potentially read and modify sensitive data, delete data and render the FTSP system unavailable.

CVSS Base Score: 9.0
CVSS Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:CC:H/I:H/A:H
CWE: CWE-279: Incorrect Execution-Assigned Permissions

Known Exploited Vulnerability (KEV) database:  No

Customers can use Stakeholder-Specific Vulnerability Categorization to generate more environment specific prioritization.

Mitigations and Workarounds

Customers using the affected software are encouraged to apply the risk mitigations, if possible. Additionally, we encourage customers to implement our suggested security best practices to minimize the risk of vulnerability.

  • Security Best Practices

ADDITIONAL RESOURCES

  • Patch: Incorrect user groups returned from FactoryTalk® Web Service, FactoryTalk® Services Platform 2.74
  • JSON CVE-2024-21915
Rockwell Automation Home
Copyright ©2022 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 홈 Chevron RightChevron Right
  2. Chevron LeftChevron Left Trust Center Chevron RightChevron Right
  3. Chevron LeftChevron Left Industrial Security Adv Chevron RightChevron Right
  4. Chevron LeftChevron Left Industrial Security Advisory Detail Chevron RightChevron Right
계속 진행하기 위해 쿠키 설정을 업데이트하십시오..
この機能には、お客様の利便性を向上させるためにクッキーが必要です。これらのクッキーを許可するように設定を更新してください:
  • 소셜 미디어 쿠키
  • 기능 쿠키
  • 성능 쿠키
  • 마케팅 쿠키
  • 모든 쿠키
귀하는 쿠키 설정을 언제든지 변경할 수 있습니다. 자세한 내용은 이곳에서 확인하십시오. 개인 정보 보호 정책
CloseClose