Our TLS-GD2 Guard Locking Switch is a positive-mode, tongue-operated interlock switch. It locks a machine guard closed until power is isolated then keeps the power isolated while the guard is open. The TLS-GD2 has three safety (N.C.) contacts and two auxiliary (N.O.) contacts.
Overview
- Power to Release or Power to Lock
- High locking force 2000 N (450 lb)
- 2 N.C. and 1 N.O. for position monitoring
- 1 N.C. and 1 N.O. or 2 N.C. for lock monitoring
- Rotatable head—4 possible key entry slots
- Conforms to EN 1088 and EN 60947-5-1
- Escape release version available
- IP69K, suitable for high-pressure, high-temperature washdown
Additional Information
Protect your people, productivity, and environment with our Safety Components and integrated Safety Solutions. We understand your factory floor challenges and can help you meet your goals with one of the broadest safety portfolios in the industry.
Specifications
Certifications
- CE Marked for all applicable directives
- cULus Listed
- TÜV Certified
Safety Classification
Type 2 interlocking device with guard locking and low coding (tongue) per ISO 14119
Functional Safety Data (related to Safety Contacts)
- B10d: > 2 x 106 operations at minimum load
- PFHD: < 3 x10-7
- MTTFd: > 385 years
- May be suitable for use in performance levels Ple or Pld systems (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Standards Compliance
- ISO 14119
- IEC 60947-5-1
Certifications apply when product is marked. See our Product Certification site for Declarations of Conformity, certificates and other certification details.
Documentation
Resource | Publication Number | Language |
---|---|---|
Safety Switches Brochure | GLSAFE-BR002 | |
Safety Switches Specifications Technical Data | SWITCH-TD001 | |
TLS-GD2 Installation Instructions | 440G-IN006 | |
TLS1-GD2, TLS3-GD2 Escape Release Installation Instructions | 440G-IN003 |