Our Ferrogard™ 3, 4 and 5 Non-contact Interlock Switches have terminal connections. These magnetically actuated safety switches offer non-contact reliability together with tolerance to misalignment.
Overview
- Non-contact actuation
- High tolerance to misalignment
- High switching current (up to 2 A, 250V AC)
- Various contact arrangements
- Terminal connections
Additional Information
Protect your people, productivity, and environment with our Safety Components and integrated Safety Solutions. We understand your factory floor challenges and can help you meet your goals with one of the broadest safety portfolios in the industry.
Product Selection
Specifications
Certifications
- CE Marked for all applicable directives
Safety Classification
- Cat. 1 Device per ISO13849-1
- Dual channel interlocks suitable for Cat. 3 or 4 systems
Functional Safety Data
- B10d: > 2 x 106 operations at min.
- PFHD: > 3 x 10-7
- MTTFd: > 385 years
- Dual channel interlock may be suitable for performance levels PLe or PLd (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics
Standards Compliance
- ISO 13849-1
- IEC/EN 60204-1
- NFPA 79
- EN 1088
- AS 4024.1
Certifications apply when product is marked. See our Product Certification site for Declarations of Conformity, certificates and other certification details.
Documentation
Resource | Publication Number | Language |
---|---|---|
Safety Switches Brochure | GLSAFE-BR002 | |
Safety Switches Specifications Technical Data | SWITCH-TD001 | |
Bulletin 440N Ferrogard Non-contact Switches Installation Instructions | FERGRD-IN001 |