Our Ferrogard™ GS1, GS2 Non-contact Interlock Switches are designed for heavy-duty applications. The GS1 is housed in a stainless steel or brass housing. The GS2 offers the same characteristic as the GS1, but in an Ex Range housing for hazardous locations.
Overview
- Non-contact actuation
- High tolerance to misalignment
- High switching current (2 A, 250V AC)
- Metal housings (IP68)
- Ex Range version available
Additional Information
Protect your people, productivity, and environment with our Safety Components and integrated Safety Solutions. We understand your factory floor challenges and can help you meet your goals with one of the broadest safety portfolios in the industry.
Specifications
Certifications
GS1 & GS2: CE Marked for all applicable directives
GS2: Ex - EExd IIC T6 Baseefa
Safety Classification
- Cat. 1 Device per ISO13849-1
- Dual channel interlocks suitable for Cat. 3 or 4 systems
Functional Safety Data
- B10d: > 2 x 106 operations at min.
- PFHD: > 3 x 10-7
- MTTFd: > 385 years
- Dual channel interlock may be suitable for performance levels PLe or PLd (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics
Standards Compliance
- ISO 13849-1
- IEC/EN 60204-1
- NFPA 79
- EN 1088
- EN 1088
- AS 4024.1
- EN 60079
- EN 61241
Certifications apply when product is marked. See our Product Certification site for Declarations of Conformity, certificates and other certification details.
Documentation
Resource | Publication Number | Language |
---|---|---|
Safety Switches Brochure | GLSAFE-BR002 | |
Safety Switches Specifications Technical Data | SWITCH-TD001 | |
Ferrogard GD2 & GS1/GS2 Non-contact Switches Installation Instructions | FRGD-IN001 |