Common Action Table for Slave Coordinate System and Master Axis

Common Action Table for Slave Coordinate System and Master Axis

All commands in this table are for the Slave Coordinate System.
Instruction
Parameters
MDCC IP Bit
MGS
Reset
MGSD
Reset
MCS
Stop Type = Coordinated Motion
Not Changed
Stop Type = Transform
Not Changed
Stop Type = All
Reset
MCSD
Reset
MAS
Stop Type = Jog
Not Changed
Stop Type = Move
Not Changed
Stop Type = Time CAM
Not Changed
Stop Type = All
Reset
MASD
Reset
MSF
Not Changed
MDF
Not Changed
Fault Action
Status Only
Not Changed
Stop Motion
Reset
Disable DRV
Reset
Shutdown
Reset
When the same Slave Coordinate System is controlled by multiple Master Axes, if one MDCC relationship that contains the Slave Coordinate System is broken, then all MDCC relationships that contain the Slave Coordinate System are broken.
Common Action Table for Master Axis
All commands in this table are for the Master Axis.
Instruction
Parameters
MDCC IP Bit
MGS
Reset
MGSD
Reset
MCS
Stop Type = Coordinated Motion
Not Changed
Stop Type = Transform
Not Changed
Stop Type = All
Not Changed
MCSD
Reset
MAS
Any Stop Type (Jog, Move, Time CAM, All)
Not Changed
MASD
Reset
MSF
Not Changed
MDF
Not Changed
Fault Action
Status Only
Not Changed
Stop Motion
Not Changed
Disable DRV
Not Changed
Shutdown
Reset
If the same Master Axis is controlling multiple Slave Coordinate System, then all MDCC relationships that contain the Master Axis are broken.