Scenario#3
- Go to the machine where FTA DataView is installed and add FT Activation Service hostname (FQDN) and IP address in thehostsfile located atC:\Windows\System32\drivers\etc\hostsdirectory.
- Go to FTA Security server to generate the certificates.
- Ensure to create the certificates using the same CA folder.
- Execute the following command to generate the certificates with FT Activation Service hostname (FQDN):create-certificate.cmd <FTA_Activation_Service_hostname (FQDN)> <ca-secret-password> <keypass> <trustpass>Refer to Table 3‑3 for the list of the supported special characters that can be used to create certificates.
- Copy the<FTA_Activation_Service_hostname (FQDN)>.p12file generated in FTA Security machine to the FT Activation Service machine and configure FT Activation Websocket Service. Refer to “FTA Activation Service”.